FCO
|
Impl.
|
Components
Affected |
Description |
A0200-1 |
M
|
XVR-1000 Graphics Accelerator (X3256A) |
SunBlade 1000/2000 and Ultra 60/80 systems
may exhibit a blank screen upon boot up with an XVR-1000 Graphics Accelerator
installed. |
A0189-1 |
U
|
Monitor 21-inch and Expert 3D Lite Graphics
PCI (X3684A) |
Ultra 60/80 and SunBlade 100/1000 systems
with Expert3D-Lite cards and certain 21-inch monitors will have to either
add or replace the monitor adaptor. |
A0186-1 |
U
|
SunPCi II (375-0131-04) and SunPCi IIpro
(375-3051-01) cards |
SunPCi II and SunPCi IIpro cards may not
respond after rapid/successive power cycling. |
A0182-1 |
C
|
18GB and 36GB IBM disk drives |
18GB and 36GB IBM disk drives experiencing
high failure rate in high humidity and high temperature environments. |
A0164-1 |
C
|
FC100/P FC-AL PCI Card (375-0040-02 or
below) |
A host system using the 375-0040-01 or
-02 FC100/P FC-AL PCI card to attach to FC-AL storage (StorEdge A5x00 and
A3500) may experience loop errors, which may affect data access to that
storage. In extreme cases, this can result in the host losing its connection
to the storage completely. However, it is more common for the loop errors
to be intermittent initially, perhaps becoming more frequent over a period
of days or a few weeks. The failures are sometimes sensitive to the data
pattern on the FC-AL loop, so they are not always reproducible with current
diagnostic software. |