Sun Microsystems, Inc.
spacer spacer
spacer   Sun System Handbook Home | Systems | Components | General Info | Search | Feedback 
spacer
black dot
 
black fade
 

Sun StorEdge[tm] D1000 Array: Repair Procedures

This section provides the most common repair procedures for the D1000. The repair procedures are provided in the following manual:

Sun StorEdge A1000/D1000 Installation and Service Manual, Chapter 3, "Removing and Replacing Components "

The table below provides the page numbers that each procedure begins on.

Component
Page Number
Tips
Disk Drive *
22 - 23
  • Swapping a disk within a clustered environment could cause issue for a customer's clustered environment in the future if the disk is the quorum device (FIN I0520-1 )
  • 18.2GB and 36GB IBM disk drives may be susceptible to early life failures problem (I0724-2).
  • Quantum (model# VK4550J or VK45J05) 4.2GB disk drives may fail to spin up. (FCO A0113-3 )
Cooling Canisters
23 - 24
  • Storage A1000 or D1000 (Dilbert) Power supplies fail with amber LED. (FCO A0162-1 )
Power Supply
25
  • A Power Supply failure on A1000/A3000 disk subsystems currently results in no alarm. ( InfoDoc 21825 )
Controller Board
26 - 28
 
* - For instructions about how to do a Hot-Plug Disk Replacement, please refer to the "Sun StorEdge D1000 Storage Guide"
WebToneWebToneWebToneWebTone
 Copyright 1994-2003 Sun Microsystems, Inc.,  901 San Antonio Road, Palo Alto, CA 94303 USA.  All rights reserved.
 Legal Terms Privacy Policy Feedback