This section provides the most common repair procedures for the
Sun Blade 1000 and Sun Blade 2000 workstations, which are included in the following
manual:
The following table provides the page numbers for each procedure.
Component |
Remove
|
Install
|
Tips |
DVD-ROM Drive |
7-5
|
7-6
|
|
CPU Module |
8-6
|
8-12
|
- Guidelines for understanding and diagnosing UltraSPARC III Level 2
(L2) SRAM Cache Memory Errors (FIN I0887-1).
- Checking torque on Sun Fire [TM] 280R, Sun Blade [TM]1000 and 2000
CPU modules (Infodoc 48429).
|
Disk Drive
|
7-2
|
7-3
|
- Power management issue causes loss of access to internal fiber channel
disks on the Sun Blade 1000/2000, Sun Fire V880, V480, and 280R (FIN
I0888-1).
- Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible
to label corruption (FIN I0816-1).
- Error installing Solaris on ST318304 FC-AL disk drives: Could not
create Solaris disk label (VTOC) (SRDB 24407).
- Recovering from a failed FCAL boot disk (SRDB 17643).
- Correcting device paths when replacing fiber boot disks after a ufsrestore
(Infodoc 40133).
|
Fan Assemblies |
6-22
|
6-23
|
|
FC-AL Backplane Assembly (contains Disk Drives) |
6-28
|
6-29
|
|
Floppy Drive |
7-9
|
7-10
|
|
Graphics Card
|
8-26
|
8-27
|
-
SunBlade 1000/2000 and Ultra 60/80 systems may exhibit
a blank screen upon boot up with an XVR-1000 Graphics Accelerator
installed (FCO A0200-1).
|
Memory |
8-31
|
8-34
|
- Too many Memory DIMMs are being unnecessarily replaced on UltraSPARC
III family of systems utilizing NG-DIMM memory (FIN I0760-1).
- Sun Blade 1000 workstations with 128MB DIMMs may have intermittant
Single Bit Correctable Errors (FCO A0181-1).
- New 256MB and 512MB LC1 DIMMs are now available ONLY for the Sun Blade
1000/2000 and Sun Fire 280R platforms (FIN I0883-1).
|
PCI Card |
8-20
|
8-22
|
-
UltraSPARC III systems may panic due to a conflict
between the Schizo 2.4 ASIC and the GigaSwift Ethernet PCI Card
(FIN I0874-1).
-
SunPCi II and SunPCi IIpro cards may not respond
after rapid/successive power cycling (FCO A0186-1).
|
Peripheral Assembly (contains DVD-ROM/tape, smart card, and floppy drive) |
7-3
|
7-10
|
|
Power Supply Assembly |
6-1
|
6-4
|
|
Replaceable Battery |
8-35
|
8-35
|
|
Smart Card Reader |
7-7
|
7-8
|
- Solaris 8 patches required for Smart Card Reader operation on Sun
Blade 100, 1000, and 2000 systems (FIN I0868-1).
|
System Board |
8-37
|
8-39
|
- UltraSPARC III and III+ based platforms could be susceptible to UCC
errors that may cause system panics (FIN I0856-1).
|
Tape Drive |
7-5
|
7-6
|
|