Sun Fire[tm] 3800 Server: Field Change Orders

The following list does not include related external storage FCOs, unless they are specific to the system.

Implementation (Impl.): 
M = Mandatory (Fully Pro-Active)
C = Controlled Pro-Active (per Sun Geo Plan)
U = Upon Failure

FCO
Impl.
Components Affected Description
A0190-1
M
cPCI I/O Board (540-4591-02 or lower) Sunfire 3800 systems with 540-4591-02 (or lower) cPCI I/O Assemblies will not support Hot Swapping of cPCI cards.
A0187-1
M
10/100 + SCSI 3U Compact PCI (501-5570-06 or lower) Sun Fire 3800 systems with cPCI cards installed will initially PANIC. Then, upon reboot, system will run fine for some period of time, but PANICs could happen more often, requiring more frequent re-boots.
A0182-1
C
18GB and 36GB IBM disk drives 18GB and 36GB IBM disk drives experiencing high failure rate in high humidity and high temperature environments.

 