Netra[tm] st A1000 Storage Array
ARY144A-36GAC 1 |
ARY144A-36GDC 1 |
AC Input Power - NEBS Level 3
4 × 9.1GB 10000 RPM Disks
Shipped w Controller 375-0007 5 |
DC Input Power - NEBS Level 3
4 × 9.1GB 10000 RPM Disks
Shipped w Controller 375-0007 |
ARY151A-72GAC 2 |
ARY151A-72GDC 2 |
AC Input Power - NEBS Level 2
4 × 18.2GB 10000 RPM Disks
Shipped w Controller 375-0007 |
DC Input Power - NEBS Level 2
4 × 18.2GB 10000 RPM Disks
Shipped w Controller 375-0007 |
ARY171A-145GAC 3 |
ARY171A-145GDC 3 |
AC Input Power - NEBS Level 2
4 × 36.4GB 10000 RPM Disks 540-4689
Shipped w Controller 375-0007 |
DC Input Power - NEBS Level 2
4 × 36.4GB 10000 RPM Disks 540-4689
Shipped w Controller 375-0007 |
ARY171B-145GAC 4 |
ARY171B-145GDC 4 |
AC Input Power - NEBS Level 3
4 × 36.4GB 10000 RPM Disks 540-5451
Shipped w Controller 375-0134 6 |
DC Input Power - NEBS Level 3
4 × 36.4GB 10000 RPM Disks 540-5451
Shipped w Controller 375-0134 |
1 The 9GB st A1000 last order date was January 2000.
2 The 18GB st A1000 was reclassified NEBS Level 2 in October 2001.
3 The 36GB st A1000 was reclassified NEBS Level 2 in October 2001.
4 The NEBS Level 3 36GB st A1000 requires drive assembly 540-5451.
5 Controllers 375-0007, 375-0015, and 375-0016 are compatible with
RM 6.0, 6.1, and 6.1.1. Firmware is not compatible with RM 6.22.
6 Controllers 375-0134, 375-0135, and 375-0136 are compatible with
RM 6.22. Firmware is not compatible with RM 6.0, 6.1, and 6.1.1.
Table Legend |
[F] = Field Replaceable Unit (FRU) |
CODE |
PART # |
DESCRIPTION |
1 1 1 |
540-3989 540-3995 540-4001 |
12-Drive AC Chassis Assembly
12-Drive DC Chassis Assembly
Empty 12-Drive Chassis Assembly |
2 |
501-4440 [F] |
12-Slot SCSI Disk Backplane |
3 |
340-5432 |
Top Cover |
4 |
540-3999 [F] |
Fan Tray |
5 5 5 |
300-1340 [F]
300-1428 [F]
300-1498 [F] |
360 Watt AC Input Power Supply
360 Watt DC Input Power Supply, Phoenix Connector
360 Watt DC Input Power Supply, Wago Connector |
6 |
340-5433 |
Bottom Cover |
7 |
540-3990 |
Front Door Assembly |
8 |
370-3760
540-3881 [F]
540-4401 [F]
540-4178 [F]
540-4689 [F]
540-4520 [F]
540-5451 [F] |
Empty 1.0" Disk Drive Slot Filler
9.1GB 10000 RPM Disk Drive FRU, NEBS Level 3
18.2GB 10000 RPM Disk Drive FRU, NEBS Level 3
18.2GB 10000 RPM Disk Drive FRU, NEBS Level 2
36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3
36.4GB 10000 RPM Disk Drive FRU, NEBS Level 2
36.4GB 10000 RPM Disk Drive FRU, NEBS Level 3 |
NS |
150-1890 [F] |
Differential Terminator, HD68 |
NS |
240-2690 |
A1000/D1000 Key |
NS |
250-1454 |
Air Filter |
NS |
375-0007
375-0015 [F]
375-0016 [F]
375-0134
375-0135 [F]
375-0136 [F]
370-3417 [F] |
Raid Controller, 8MB MPU + 16MB RPA w/ Battery
Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery
Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery
Raid Controller, 8MB MPU + 16MB RPA w/ Battery
Raid Controller FRU, 8MB MPU + 16MB RPA w/o Battery
Raid Controller FRU, 16MB MPU + 64MB RPA w/o Battery
Battery |
NS NS |
530-2729 [F]
530-2751 |
SCSI Cable, 90° HD68 to VHDCI68, 2M (X992A)
SCSI Cable, 90° HD68 to VHDCI68, 4M (X993A) |
NS NS |
530-2846 [F]
530-2847 |
Right 90° HD68 to VHDCI68, 2M (X959A)
Right 90° HD68 to VHDCI68, 4M (X947A) |
NS NS NS |
595-5112 250-1454 340-5439 |
EMI Shield and Air Filter, Option 994
Foam Air Filter
EMI Shield |
NS NS |
595-5350 340-5435 |
19-inch Rack Mount Kit
Mounting Bracket (×2) |
NS NS |
595-5117 340-4463 |
23-inch and 24-inch Rack Mount Kit, Option 6907
Mounting Bracket (×2) |
NS NS |
595-5116 340-5559 |
600 mm Rack Mount Kit, Option 6909
Mounting Bracket (×2) |
|