FCO
|
Impl.
|
Components
Affected |
Description |
A0184-1 |
C
|
SCI SBus Board (370-2868-01) |
SCI cards installed in E10000 systems
may not initialize properly. |
A0176-2 |
C
|
Power Cables (530-2379-01, 530-2675-01,
530-2674-01, 530-2266-02 or less, 530-2380-01, 530-2568-02 or less, 530-2567-02
or less, 530-2265-02 or less, 530-2503-01 |
E10K power cords with pre-tinned wires
violates UL 1950 standard |
A0163-1 |
C
|
Differential Ultra/Wide SCSI, UDWIS/S
(370-2443-01) |
Systems with large quantities of UDWIS/SBus
Host Adapters installed may not come up after reboot due to miscommunication
between the SCSI host and the target. Large configurations with many UDWIS/SBus
Host Adapter cards are more vulnerable due to higher probability of encountering
the reboot problem. |
A0161-1 |
C
|
SunFastEthernet (SunSwift) SBus Card (501-2739-05) |
Enterprise 10000 systems with (SunSwift)
Cards could experience intermittent but fatal errors at power up. |
|
M
|
SBus I/O Board (501-4349) |
Installation of certain SBus cards in
slot 1 of E10000 having older I/O Mezzanine Boards has been found to cause
unpredictable behavior, including resets, offlines, and undetected data
corruption. |
A0138-1 |
C
|
SBus/FC SOC+ Host Adapters |
SBus/FC SOC+ Host Adapters may experience
recoverable data transfer read errors. This can result in individual user
applications, like Oracle, to stop running. |
A0127-1 |
M
|
QEC SBus Card (501-2062)
|
Quad-FastEthernet SBus X1049A cards now
available for substitution for E10000 systems shipped with the Quad-Ethernet
SBus X1058A cards. |
A0125-1 |
M
|
AC Power Cord |
A.C. Power Cord inside E10000 can become
damaged by system leveling foot. At the right rear of the E10000 system
cabinet, the leveling foot can bite into the sequencer A.C. power cord when
it is adjusted up to move the E10000 system. |
A0124-1 |
U
|
System Board (501-4786-01, 501-4347-09
or below) |
Early life failures on the E10000 system
board could cause system to crash. |
|
C
|
SSP, Control Board |
Slow E10000 SSP to control board connection
resulting in various system errors. Consequently, the control board resets
frequently. Domain bring-ups may fail, SNMP access may fail, and/or console
timeouts may occur. |
A0103-1 |
M
|
Control Board (501-4345-05, 501-4345-04) |
E10000 hang created by control board going
into a continuous reset mode. |
A0096-1 |
M
|
AC Power Sequencer (300-1290-02) |
Power sequencer and power cords are non-compliant
with safety standard UL1950/EN60950. |