This section provides the most common repair procedures for the
Sun Fire 280R. The following links are located in the Sun
Fire 280R Server Service Manual (806-4807).
Component |
Remove
|
Install
|
Tips |
Air Guide |
|
|
|
CPU Module |
|
|
- Service procedures for replacement of early-release UltraSPARC[tm]
III modules with pre-fetch pipeline problems (FIN I0658-1).
- Guidelines for understanding and diagnosing UltraSPARC III Level 2
(L2) SRAM Cache Memory Errors (FIN I0887-1).
- Checking torque on Sun Fire [TM] 280R, Sun Blade [TM]1000 and 2000
CPU modules (Infodoc 48429).
|
Disk Drive |
|
|
- Power management issue causes loss of access to internal fiber channel
disks on the Sun Blade 1000/2000, Sun Fire V880, V480, and 280R (FIN
I0888-1).
- Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible
to label corruption (FIN I0816-1).
- Error installing Solaris on ST318304 FC-AL disk drives: Could not
create Solaris disk label (VTOC) (SRDB 24407).
- Recovering from a failed FCAL boot disk (SRDB 17643).
- VxVM - procedure to replace internal disks in SunFire 280R systems
(Infodoc 40842).
- Correcting device paths when replacing fiber boot disks after a ufsrestore
(Infodoc 40133).
|
Disk Drive (Hot-Plug Operation) |
|
|
- Power management issue causes loss of access to internal fiber channel
disks on the Sun Blade 1000/2000, Sun Fire V880, V480, and 280R (FIN
I0888-1).
- Removing and Replacing the Sun Fire 280R (Littleneck), 480R (Cherrystone),
or 880R (Daktari) hot-pluggable internal disk drives (SRDB 40517).
- VxVM - procedure to replace internal disks in SunFire 280R systems
(Infodoc 40842).
- Correcting device paths when replacing fiber boot disks after a ufsrestore
(Infodoc 40133).
|
DVD-ROM Drive |
|
|
|
Fan Tray Assembly |
|
|
- Some Sun Fire 280R A35-AA ATO systems do not need fan tray upgrades
when migrating to 900MHz or 1050MHz processors (FIN I0894-1).
|
FC-AL Backplane |
|
|
|
ID SEEPROM Module |
|
|
|
Memory |
|
|
- Too many Memory DIMMs are being unnecessarily replaced on UltraSPARC
III family of systems utilizing NG-DIMM memory (FIN I0760-1).
- New 256MB and 512MB LC1 DIMMs are now available ONLY for the Sun Blade
1000/2000 and Sun Fire 280R platforms (FIN I0883-1).
|
PCI Card |
|
|
-
UltraSPARC III systems may panic due to a conflict
between the Schizo 2.4 ASIC and the GigaSwift Ethernet PCI Card
(FIN I0874-1).
-
SunPCi II and SunPCi IIpro cards may not respond
after rapid/successive power cycling (FCO A0186-1).
|
Power Distribution Board |
|
|
|
Power Supply |
|
|
|
Removable Media Assembly |
|
|
|
RSC Card |
|
|
|
System Board |
|
|
- UltraSPARC III and III+ based platforms could be susceptible to UCC
errors that may cause system panics (FIN I0856-1).
|
Tape Drive |
|
|
|