This section provides the most common repair procedures for the
Ultra 5 workstation. The written procedures below are links to the Sun
Ultra 5 Service Manual (805-7763).
Component |
Remove
|
Install
|
Tips |
CD-ROM Drive |
|
|
- Booting from CD-ROM on Ultra 5/10 systems might not succeed unless
the system OBP is updated (FIN I0770-1).
|
CPU Fan Assembly |
|
|
|
CPU Module |
|
|
- The system board must have the minimum OBP version (3.19v4) installed
for the Ultra 5/10 333MHZ Sapphire Red CPU module; otherwise, the system
will be non-operational (FIN I0528-1).
- Unable to boot after replacing CPU in Ultra 5/10 (SRDB 21117).
|
Disk Drive (Primary) |
|
|
-
Ultra 5/10 workstations may encounter uncorrectable
data errors on IDE disks during boot after using shutdown -y -i5 -g0
command (FIN I0779-1).
- After adding or replacing a disk drive, the following error occurs
when attempting to use the format utility: "corrupt label - wrong magic
number" (FIN I0385-1).
- 18GB and 36GB IBM disk drives experiencing high failure rate in high
humidity and high temperature environments (FCO A0182-1).
|
Disk Drive (Secondary) |
n/a
|
|
-
-
Ultra 5/10 workstations may encounter uncorrectable
data errors on IDE disks during boot after using shutdown -y -i5 -g0
command (FIN I0779-1).
- After adding or replacing a disk drive, the following error occurs
when attempting to use the format utility: "corrupt label - wrong magic
number" (FIN I0385-1).
- 18GB and 36GB IBM disk drives experiencing high failure rate in high
humidity and high temperature environments (FCO A0182-1).
|
Floppy Drive |
|
|
|
Front Bezel |
|
|
|
Power Supply |
|
|
|
Speaker Assembly |
|
|
|
Memory (DIMM) |
|
|
- Ultra 5 and Ultra 10 systems might not boot if Micron memory and OBP
3.25.2 (or earlier) are installed (FIN I0598-1).
|
NVRAM/TOD |
|
|
- New NVRAM (525-1817) is incompatible with the Ultra 5/10 system board
(375-0079), so a new system board (375-0115) was created for the new
NVRAM (I0596-1).
|
PCI Card |
|
|
-
SunPCi II and SunPCi IIpro cards may not respond
after rapid/successive power cycling (FCO A0186-1).
- PCI cards in Ultra 10 not accessible due to mechanical alignment and
seating problems with the PCI Riser card (FCO A0152-1).
- Ultra 5/10 systems may encounter errors when booting from SCSI devices
attached to Dual Ultra SCSI PCI cards (FIN I0386-1).
|
PCI Riser Board |
|
|
|
System Board |
|
|
|