FIN |
Impl.
|
Components
Affected |
Description |
I0922-1 |
R
|
A1000 Battery (370-3417-01)
SS CD ASSY RAID Manager 6.1 (798-088-01)
RAID Manager 6.1.1 (798-0522-01)
RAID Manager6.1.1 Update 1 (798-0522-02)
RAID Manager6.1.1 Update 2 (798-0522-03)
CD, SUN STOREDGE RAID Manager6.22 (704-6708-10)
CD, SUN STOREDGE RAID Manager6.22.1 (704-7937-05)
|
Inaccurate battery failure analysis for Sun StorEdge A1000 Arrays may
result in false alarms and unnecessary system downtime for customers,
and unnecessary service calls for support personnel. |
I0886-1 |
R
|
Manual Set Sun RSM Array 2000 (825-3869-02)
RAID Manager 6.1 CD (798-0188-01)
RAID Manager 6.1.1 (798-0522-01)
RAID Manager 6.1.1 Update 1 (798-0522-02)
RAID Manager 6.1.1 Update 2 (798-0522-03)
RAID Manager 6.22 CD (704-6708-10)
RAID Manager 6.22.1 CD (704-7937-05) |
Systems with StorEdge A1000, A3x00 or A3500FC Arrays, which are
configured to run under volume manager software, may experience
database or application problems when repeated disk I/O error retries
occur. Excessive RDAC and Solaris disk driver retry attempts on I/O
errors may result in database managers (such as Oracle) or applications
to timeout. This may cause the applications to crash or run very
slowly following an I/O timeout. |
I0865-1 |
R
|
CD Sun StorEdge RAID Manager 6.22 (704-6708-10(
CD Sun StorEdge RAID Manager 6.22.1 (704-7937-05) |
Disks in StorEdge A1000/A3x00/A3500FC arrays may sometimes be shown as
having physical device paths in addition to pseudo device paths with
the 'format' utility. Although the disks and arrays will continue to
function normally, this issue may cause confusion for system
administrators and support personnel.
This issue applies to any system type with StorEdge A1000/A3x00/A3500FC
arrays with Raid Manager 6.22 or 6.22.1 installed. |
I0860-1 |
C
|
RAID Manager 6.1.1 (798-0522-01)
RAID Manager 6.1.1 Update 1 (798-0522-02)
RAID Manager 6.1.1 Update 2 (798-0522-03)
CD, SUN STOREDGE RAID Manager 6.22 (704-6708-10)
CD, SUN STOREDGE RAID Manager 6.22.1 (704-7937-05) |
Installation of Patch 112126 for RAID Manager 6.22.1 (RM 6) fails on
Solaris 9. This patch was not designed to be loaded on Solaris 9,
although RM 6 and the patch contents function properly on Solaris 9. |
I0845-1 |
R
|
RAID Manager 6.1.1 & Update 1/2 (798-0522-03 or lower)
RAID Manager 6.22 CD (704-6708-10)
RAID Manager 6.22.1 CD (704-7937-05) |
Sun StorEdge A1000/A3x00/A3500FC Arrays with RAID Manager 6 (RM6) may
hang for up to 8 minutes when they contain more than one failed IBM disk
drive. |
I0828-1 |
R
|
CD Sun StorEdge RAID Manager 6.22.1 (704-6708-10) |
LUNs may become inaccessible after upgrading from RM 6.22 to
6.22.1 or after adding unformatted disk drives to RM 6.22.1. |
I0786-1 |
R
|
RAID Manager 6.1 CD (798-0188-01)
RAID Manager 6.1.1 (798-0522-01)
RAID Manager6.1.1 Update 1 (798-0522-02)
RAID Manager6.1.1 Update 2 (798-0522-03)
SUN STOREDGE RAID Manager 6.22 CD (704-6708-10)
A1000
A3000
A3500
A3500FC |
Newly installed A1000/A3x00/A3500FC
arrays might not be useable under Solaris 8 when added with the RAID Manager
'hot_add' command. The LUNs for these arrays will not be recognized and
are not listed in the output of 'format'. This FIN will describe the problem
and provide the proper procedures for adding these arrays under Solaris
8. |
I0782-1 |
R
|
A1000 Array
A3000 Array
A3500 Array
A3500FC Array |
Adding new disk drives to StorEdge
A1000/A3x00 arrays must be done properly to avoid loss of LUNs. |
I0744-1 |
R
|
Sun StorEdge RAID Manager
6.22 CD (704-6708-10)
Sun StorEdge RAID Manager 6.22.1 CD (704-7937-05) |
RM 6.22.1 problems reported
in BugId 4521759 have been fixed with Patches 112126-01 for Solaris 8 and
112125-01 for other Solaris versions above Solaris 2.5.1. |
I0738-1 |
R
|
Sun StorEdge RAID Manager
6.22 CD (704-6708-10)
Sun StorEdge RAID Manager 6.22.1 CD (704-7937-05) |
Access to Oracle, Sybase and
other databases on the StorEdge A1000 and A3x00 Array may fail when PatchID
108834-03 (or higher) or 108553-03 (or higher) have been installed on RAID
Manager 6.22, or if running RAID Manager 6.22.1. Access to database logs
or other files that are directly stored on A1000/A3x00/A3500FC LUNs can
also appear to fail. Non-root users can not access raw partitions. |
I0727-1 |
R
|
Sun StorEdge RAID Manager
6.22 CD (704-6708-10)
Sun StorEdge RAID Manager 6.22.1 CD (704-7937-05)
A1000
A3500
A3500FC |
The information in this FIN
is provided as a guideline for authorized Enterprise Services Field Representatives
in recovering A1000/A3x00 controller C numbers after a device path changed
due to reboot -r. |
I0724-2 |
R
|
18 GB and 36 GB IBM disk drives |
Failure analysis results have
highlighted a significant failure rate for Drive Not Ready (DNR) on returned
IBM 18GB & 36GB disk drives. These failures have been observed to occur
as a result of the disk drives either been stored or operated in an extremely
hot and humid environments. |
I0709-1 |
R
|
Sun StorEdge RAID Manager
6.22 CD (704-6708-10)
Sun StorEdge RAID Manager 6.22.1 CD (704-7937-05) |
After replacing a controller
FRU on A1000/A3x00/A3500FC with RM 6.22.1, the NVSRAM must be reloaded. |
I0698-1 |
R
|
Sun StorEdge RAID Manager
6.22 CD (704-6708-10) |
Installing RAID Manager 6.22
patches 108834-09 and 108553-09 may generate false or misleading warning
messages "UNRESPONSIVE DRIVES" when running the 'healthck' or 'drivutil'
commands and report excessive false 9501 messages. |
I0688-1 |
R
|
MNL Set, SUN RSM ARRAY 2000
(825-3869-02)
RAID Manager 6.1 CD (798-0188-01)
RAID Manager 6.1.1 (798-0522-01)
RAID Manager6.1.1 Update 1 (798-0522-02)
RAID Manager6.1.1 Update 2 (798-0522-03)
SUN STOREDGE RAID Manager 6.22 CD (704-6708-10) |
Raid Manager 6.22 has been
qualified by SUN QAST to run on Solaris 2.5.1. |
I0685-1 |
R
|
RAID Manager 6.1 CD (798-0188-01)
RAID Manager 6.1.1 (798-0522-01)
RAID Manager6.1.1 Update 1 (798-0522-02)
RAID Manager6.1.1 Update 2 (798-0522-03)
SUN STOREDGE RAID Manager 6.22 CD (704-6708-10)
|
This FIN highlights the precautions that should be followed if performing
Solaris Operating Environment upgrades on the system with Sun StorEdge
RAID Manager software installed, Absence of these precautions could result
in data loss or possibly the data corruption. When upgrading from Solaris
2.6 to any higher Solaris version, a copy of the file /kernel/drv/sd.conf
needs to be backed up and then restored after the upgrade. If this action
is not taken then an upgrade will result in repeated error messages upon
boot up and an inability to scan the array module
|
I0653-1 |
R
|
RSM array shelves (370-2343) |
RSM Array shelves may collapse
under weights greater than 40lbs (18.2kg), causing system damage or personal
injury. |
I0619-1 |
R
|
rm 6.1.1 (798-0522-01 )
rm 6.1.1 Update 1 (798-0522-02)
rm 6.1.1 Update 2 (798-0522-03)
rm 6.22 CD (704-6708-10)
|
Proper procedures for booting
from StorEdge A1000 or A3x00 hardware RAID device, including known issues
and problems. |
I0613-1 |
R
|
A1000,8/16MB Controller
(375-0016-03)
A1000,16/64MB Controller
(375-0015-03)
A1000,8/16MB Controller
RM6.22 (375-0135-01)
A1000,16/64MB Controller
RM6.22 (375-0136-01) |
When a failed controller board
is replaced in the A1000 StorEdge Array, it is necessary to first verify
the RAID Manager software version being used, the controller firmware level,
and the controller memory size. Failure to do so may result in the wrong
FRU being installed. This will result in incompatibility between the controller
firmware and the RAID Manager software. This can cause LUN's under the A1000
to be inaccessible and cause data access problems. |
I0612-1 |
R
|
rm 6.1.1 (798-0522-01 )
rm 6.1.1 Update 1 (798-0522-02)
rm 6.1.1 Update 2 (798-0522-03)
rm 6.22 CD (704-6708-10) |
rm6 may detect a non-existent
2MB dacstore on factory formatted hard disk drives.
When adding new drives to the A1000, A3x00, or A3x00FC user may be unable
to create LUNs or replace failed drives within existing LUNs using RM6.1.1
or RM6.22. |
I0589-1 |
C
|
Dual Differential Ultra/Wide
SCSI PCI (X6541A or 375-0006) |
glm.conf file must be modified
to support more than 8 LUNs on any PCI-SCSI connected A1000/A3x00 using any
version of RM 6.Attempting to support for more than 8 LUNs on a system using
the PCI UltraSCSI differential dual channel host adapter connected to an A3x00/A1000
array can cause loss of access to the data on those arrays. Attempting to
access that data will produce an error message "Unable to scan module". |
I0579-1 |
C
|
Differential Ultra/Wide SCSI
UDWIS/S (370-2443-01 & -02) |
Systems with UDWIS/SBus Host
Adapter slow to a halt under heavy IO loads and the Console displays "SCSI
transport failed" error messages. |
I0573-2 |
C
|
Sun RSM Array 2000 Mnl (825-3869-02)
rm 6.1 CD (798-0188-01)
rm 6.1.1 (798-0522-01 )
rm 6.1.1 Update 1 (798-0522-02)
rm 6.1.1 Update 2 (798-0522-03)
rm 6.22 CD (704-6708-10) |
StorEdge A1000, A3000, A3500,
A3500FC requires the existence of LUN 0 for proper operation. This FIN has
critical impact to all A3X00/A3500FC/A1000 configurations on all Sun Ultra
Enterprise platforms using all versions of Solaris/SunOS. Ultra Systems
experiencing faults documented in this FIN can be down for extended periods
or until LUN 0 is installed. |
I0569-1 |
R
|
Differential Ultra/Wide SCSI
UDWIS/S (370-2443-02) |
UDWIS/SBus Host Adapter with
isp-fcode 1.28 can cause "invalid command" during probe-scsi-all or boot
-hv from a StorEdge D1000. |
I0566-2 |
R
|
n/a |
Patch Id 108553
is required to run Solaris 8 with Raid Manager 6.22. RAID Manager 6 is currently
not supported on Solaris 8, attempting to boot Solaris 8 with RM 6.22 installed
will produce an error message as shown below; "rdriver not loading, ie "drvconfig:
driver failed to attach: rdriver". This means that the data on A3x00/A1000
arrays will not be accessible under Solaris 8. This applies to all versions
of RM 6.0, 6.1, 6.1.1, and 6.22 when running Solaris 8. (6-12-00) |
I0552-1 |
C
|
Differential Ultra/Wide SCSI
UDWIS/S (370-2443-0X)
Single Ended Fast/Wide SCSI SWIS/S (370-1703-0X)
Differential Fast/Wide SCSI DWIS/S (370-1704-0X)
|
When a SCSI bus reset is issued
under heavy i/o, the isp driver causes the sd driver to report i/o errors.
Any configuration with an isp driver version prior to the fix to bug 4280783
may be affected. The most likely configuration to experience this problem
is multi-hosted and shared storage devices e.g. A3x00 (SCSI version only),
A1000, D1000 etc. connected to differential SCSI cards using the isp driver,
or MultiPack, UniPack etc. connected to single-ended SCSI cards using the
isp driver. |
I0551-1 |
R
|
rm 6.1.1 CD (798-1036-01)
rm 6.22 CD (704-6708-10) |
Boot process and controller
on-line process may take hours in systems with large StorEdge A3000, A3500
or A1000 configs. |
I0547-1 |
C
|
Differential Ultra/Wide SCSI
UDWIS/S (370-2443-01) |
Intermittently, SCSI devices
connected to a UDWIS card may not be usable after a reboot. This can prevent
a system from booting if the UDWIS card connected to the boot device is
affected. This problem is due to some issues in FCode versions less than
1.28 in the UDWIS card. When it is booting, the card fails to send a SCSI
bus reset, or the SCSI bus reset is not held long enough to meet the SCSI
specification, or the card fails to initialize correctly. This leads to
the attached SCSI devices failing to negotiate correctly with the host. |
I0520-1 |
C
|
n/a |
Swapping a disk within a clustered
environment could cause issue for a customer's clustered environment in
the future if the disk is the quorum device. Failure to notice that the
failed disk is the quorum device and swapping it will cause the cluster
to invoke manual intervention if the cluster goes into failure fencing or
split brained activities. |
I0511-2 |
C
|
Sun Enterprise VM 2.5
Sun Enterprise VM 2.6
Sun StorEdge Volume Manager 2.6
Veritas Volume Manager 2.5
Veritas Volume Manager 2.6
|
Enabling DMP under Volume
Manager 2.5/2.6 with RDAC and RSM2000/A3x00/A3500FC may cause private regions
to be lost. This FIN is not applicable to VxVM 3.0.2 or higher. There have
been several reported cases where systems with an attached RSM2000/A3x00/A3500FC
with Volume Manager on top of RM6 LUNs have experienced the corruption of
the Volume Manager configurations. The purpose of this FIN update is to
notify that VxVM 3.0.2 and A1000s are not affected. |
I0509-1 |
C
|
Sun RSM Array 2000 Mnl (825-3869-02)
rm 6.1 CD (798-0188-01)
rm 6.1.1 (798-0522-01 )
rm 6.1.1 Update 1 (798-0522-02)
rm 6.1.1 Update 2 (798-0522-03) |
In order for RM 6 software
to configure multiple LUNs, it adds entries to the sd.conf and rdriver.conf
files. The add16lun.sh script is a case in point as it enlarges the sd.conf
for 16 LUNs for all targets. However, there is bug in the Solaris kernel
that sometimes causes a panic if a *.conf file is greater than 8k bytes.
|
I0505-2 |
R
|
Sun RSM Array 2000 Mnl (825-3869-02)
rm 6.1 CD (798-0188-01)
rm 6.1.1 (798-0522-01 )
rm 6.1.1 Update 1 (798-0522-02)
rm 6.1.1 Update 2 (798-0522-03) |
When a RAID 0 LUN with a mounted
file system experiences a failure that shows a "dead" LUN status, the recovery
procedure needs to be augmented. If the Recovery Guru is unable to unmount
the file system, the recovery will not complete, even though there is a
message indicating the recovery can proceed even with mounted file systems.
Note that RAID 0 LUN's behave like non-RAID devices. The processes doing
I/O to the dead LUN need to be stopped and Recovery Guru re-run so the unmount
will complete and the recovery can proceed. |
I0473-1 |
R
|
rm 6.1.1 Update 1 (798-0522-02) |
Solaris 7 upgrade recommendations
for StorEdge A3x00/A1000. In reference to BugId# 4141207
"No support for A1000 on Solaris 2.7". The following symptoms may be encountered:
The driver succeeds in attaching but the lun devices for A1000 under /dev/rdsk
are not mapped to pseudo/rdnexus@3/rdriver@5,4:a,raw as expected. |
I0447-1 |
C
|
Patch 105463-05
Sun Enterprise VM 2.5
Sun Enterprise VM 2.6 |
When patch 105463-05
(SEVM2.5 patch) is applied on an operational system, and the system is rebooted,
some storage devices may appear to be missing or longer listed. This symptom
may also be experienced when installing EVM2.6, upon execution of vxinstall,
not all of the storage devices on the system will be available for EVM to
use. This may happen on systems that have a mixture of storage devices,
although there have been reports of systems with a single SPARCstorage Array
attached, experiencing loss of access to some of the disks after application
of this patch. The device loss is due to a modification that had been made
to the DMP driver binary file in this release of the patch. Systems that
have disabled DMP operation will not experience this problem. |
I0440-1 |
C
|
rm 6.1.1 (798-0522-0X) |
RM6.1.1 with StorEdge A1000,
A3000 or A3500 may experience status check problems. Reference bugids 4164090,
4153015,
4094014,
& 4023075 |
I0439-1 |
R
|
A1000/D1000 Rackmount Kit
(X9653A)
StorEdge A1000/D1000
Rackmount Installation Guide
(805-2626-10 & 805-2626-11) |
A small quantity of A1000/D1000
rackmount kits (X9653A) have been recently shipped to customer sites with
an insufficient amount of screws needed to properly complete the rackmount
installation. The affected rackmount kits (X9653A) shipped with four (4)
installation screws as opposed to the twenty (20) screws that are needed
for the installation. In addition, the Sun StorEdge A1000/D1000 rackmount
installation manual (805-2626-10) incorrectly illustrates that only four
(4) screws are needed to complete the A1000/D1000 rackmount installa- tion.
|