Sun Microsystems, Inc.
spacer spacer
spacer   Sun System Handbook Home | Systems | Components | General Info | Search | Feedback 
spacer
black dot
 
black fade
 

Sun Enterprise[tm] 10000 Server: Field Information Notices

The following list does not include related external storage FINs, unless they are specific to the system.

Implementation (Impl.):
M
= Mandatory (Fully Pro-Active)

C
= Controlled Pro-Active (per Sun Geo Plan)

R
= Reactive (As Required)

FIN

Impl.
Components Affected Description
I0849-1
R
CPU Modules New capability is available on E10000 systems to identify MSRAM modules from POST output.
I0838-1
R
Sun Dual FE + Dual SCSI PCI Adapter (X2222A / 501-5727-03) Sun Enterprise 10000 systems will fail to boot over the network from a down rev Dual Fast Ethernet and Dual SCSI PCI Adapter. This can lead to unexpected system downtime when attempting to perform a network install.
I0827-1
R
SSP 3.4, SSP 3.5 SSP 3.4 and 3.5 'showfailover' output may be inconsistent with the actual E10K clock source and may lead to domain arbstops when an active control board is hot-swapped.
I0821-1
R
SBus Dual FC Host Adapter (375-3048-01) Customers using SBus Dual FC Adapter (X6757A) at Rev. 50 may notice slow performance on sequential write operations.
I0812-1
R
Solaris 8 2/02 (Update 7) DVD Installation DVD installation of Solaris 8 Update 7 on Sun Fire 15K and Sun Enterprise 10000 servers does not execute platform specific finish scripts, which leads to loss of functionality for these systems. The installation will complete and domains can be booted, but System Controller or SSP functions will be impacted.
I0805-1
R
Memory DIMM (501-2654-01, 501-2653-01) DIMMs are being unnecessarily replaced on Enterprise 10000 servers.
I0766-1
C
Dynamic Reconfiguration and VxFS 3.3.3 VxFS 3.3.3 memory allocation error causes DR to be unable to detach or system to appear hung on E10K under Solaris 2.6, 7, and 8.
I0730-1
C
SSP A global arbstop may occur in certain instances on Enterprise 10000 servers.
I0728-1
R
MC Timeout Arbstop All MC Timeout Arbstop problems on E10K systems should be escalated to CPRE-HSG for review.
I0724-2
R
18 GB and 36 GB IBM disk drives Failure analysis results have highlighted a significant failure rate for Drive Not Ready (DNR) on returned IBM 18GB & 36GB disk drives. These failures have been observed to occur as a result of the disk drives either been stored or operated in an extremely hot and humid environments.
I0712-1
R
FC-AL GBIC Module 100MB/s (option X6731A, 370-2303) This FIN is to inform the field of a new style GBIC that will be shipping with A5X00 Storage Arrays. Installing a FINISAR GBIC in any platform other than A5X00 will result in a restricted access condition which may result in unanticipated downtime.
I0707-1
R
464MHz CPU Modules Booting from the network can fail with Solaris 2.5.1 and Solaris 2.6 when using 464MHz or faster processors.
I0689-1
R
Torque Tool To torque correctly on a specific Sun Products, refer to the Torque tool matrix for correct Torque Bit Type/Size and Torque Setting.
I0687-1
C
Fans Failing fan on Enterprise 10000 server may cause other fans to turn off.
I0679-1
R
SSPs E10000 SSP's may fail POST when outdated ssp_backup files are restored.
I0678-1
R
SBus bracket kits (560-2517-01, 565-1404-01, 565-1673-01) SBus bracket kit may be needed when installing SBus cards in Enterprise 10000 systems.
I0675-1
R
System Board, Centerplane The current E10000 System Board insertion technique places improper loads on the System Board/Centerplane mating connector and may damage the connector.
I0673-1
R
Power Supplies Internal data connectors in an E10K may come loose during shipment, causing power supplies to not function.
I0653-1
R
RSM array shelves (370-2343) RSM Array shelves may collapse under weights greater than 40lbs (18.2kg), causing system damage or personal injury.
I0664-1
C
SSP Rebooting the System Service Processor (SSP) of an E10000 system while SSP processes are active can cause all domains to stop.
I0647-1
R
FC-AL SBus Card (FC100/S 501-3060-06)
FC-AL SBus Card (FC100/S 501-5202-03)
FC-AL SBus Card (FC100/S 501-5266-04)

Fcode upgrade instructions for the FC100/S Host Adapter supplied with the following luxadm patches can lead to obsolete fcode being installed.

  • 105310-14 SunOS 5.5.1: Patch for socal, sf driver, and luxadm
  • 105375-25 SunOS 5.6: sf & socal driver patch
  • 107473-06 SunOS 5.7: luxadm patch
  • 109529-03 SunOS 5.8: luxadm, liba5k and libg_fc patch

The latest fcode for the FC100/S Host Adapter has been moved to patch 109400-03 for all versions of Solaris. This change is not reflected in the README files of the luxadm patches currently available (105310, 105375, 107473 and 109529). These patches still provide a lower version of the FC100/S fcode (1.11) and give instructions for installing it.

I0646-1
C
SSP SSP 3.4 failover may prevent successful patch installation in a dual SSP configuration.
I0644-1
R
OpenSSP software New support policy for third party application software on the E10000 System Service Processor (SSP).
I0640-1
R
System Boards E10000 systems experiencing excessive DTAG errors should be reported to HES Engineering for problem resolution.
I0624-1
R
COD Systems E10000 Capacity On Demand systems are not configured to enable automatic data collection.
I0616-1
C
CPU Module Solaris kernel patches provide improved handling and reduction of CPU, Ecache, and main memory errors in UltraSPARC systems. All customers on Solaris 2.5.1, 2.6, 7 and 8 are encouraged to consider upgrading to these kernel patches as they become available.
I0614-1
R
8-Pack Air Filter (555-1897-01) New guidelines have been introduced for air filter maintenance on E10000 systems.
I0611-1
R
AC Power Sequencer Some E10K systems are being shipped to customers with all unipack boot disks for each domain plugged into the same AC power. If an AC power sequencer fails in an E10000 with two unipacks as boot devices for the same domain and powered by the same AC power sequencer, the domain will crash and will remain unbootable until the power sequencer is replaced or the power cable on one of the unipack boot devices is moved to another power sequencer.
I0593-1
C
Netcon Logging, SSP 3.1.1 Netcon logging should be enabled for all E10000 Servers.
I0582-1
R
Solaris 8 Sun Enterprise 10000 server domain install instructions are incorrect in Solaris 8.
I0579-1
C
Differential Ultra/Wide SCSI, UDWIS/S (370-2443-01/02); Systems with Ultra DWIS/SBus Host Adapter slow to a halt under heavy IO loads and the Console displays "SCSI transport failed" error messages. The failures will cause timeouts on the SCSI bus and drastically slow down the IO operations and eventually hang the system.
I0578-1
R
Alternate Pathing Documentation The Sun Enterprise Alternate Pathing (AP) 2.3 AnswerBook package is missing from the AP 2.3 release.
I0570-3
R
CPU Modules The current diagnostic procedure to identify the faulty CPU module from CPU Ecache parity errors is flawed, and it could easily lead to the wrong CPU being replaced. Make sure to follow the appropriate instructions and guidelines to CORRECTLY identify Ecache panic fault diagnosis on multi-cpu systems.
I0569-1
R
Differential Ultra/Wide SCSI, UDWIS/S (370-2443-02) Any system installed with a UDWIS/S (isp-fcode 1.28) has the possibility of displaying "invalid command" messages during POST, "probe-scsi-all" at the ok prompt, booting IF the variable "diag-switch?" is set to "true", or boot -hv from external storage..
I0567-1
R
CPU Modules Cleaning kit available for cleaning silicon oil from CPU module on the system board.
I0562-1
C
Autoconfig Autoconfig syntax error can cause global arbstops, resulting in downtime for every running domain on an E10000 systems platform.
I0560-1
R
Dynamic Reconfiguration Due to various bugs discovered with Dynamic Reconfiguration affecting the Enterprise 10000 Server, a website has been created to list both problem and resolution of the bugs encountered (http://hes.west/dhpg/#dr). At this point, most bugs have been resolved with fixes in the latest Kernel Update patch but there are a few still outstanding which could potentially impact production.
I0555-1
C
Alternate Pathing Software Automatic ap_reboot feature has been disabled within EDD/Alternate Pathing configuration.
I0552-1
C
Differential Ultra/Wide SCSI, UDWIS/S (370-2443-01); Differential Ultra/Wide SCSI, DWIS/S (370-1704-0X); Single-Ended Fast/Wide SCSI, SWIS/S (370-1703-0X) SCSI devices (especially in a multi-hosted configuration) may go offline after isp errors. The most likely configuration to experience this problem is multi-hosted and shared storage devices connected to differential SCSI cards using the isp driver, or MultiPack/ UniPack connected to single-ended SCSI cards using the isp driver.
I0547-1
C
Differential Ultra/Wide SCSI, UDWIS/S (370-2443-01) Intermittently, SCSI devices connected to a UDWIS card may not be usable after a reboot. This can prevent a system from booting if the UDWIS card connected to the boot device is affected.
I0539-1
R
Alternate Pathing Software Enterprise Server Alternate Pathing 2.2 product is incorrect on the Solaris 8/99 Media Kit. The Solaris 8/99 version is missing several bug fixes and is not patchable via normal patch mechanisms.
I0536-2
R
A3X00 E10000 systems with an A3X00 attached may encounter Dynamic Reconfiguration errors.
I0534-1
C
FDDI/S SAS (370-3142), FDDI/S DAS (370-3143) E10000 using FDDI 6.0 software may encounter broken pipe errors and Dynamic Reconfiguration problems.
I0530-1
C
Solaris 2.6 The Enterprise 10000 may be susceptible to system hangs if ISM is not enabled.
I0527-1
R
SSP

Documentation corrections for rebuilding an E10000 SSP boot disk or upgrading the OS on an SSP.

I0510-1
C
Control Board Following the instructions for control board switch-over with SSP 3.1 will cause all domains to panic, after the switch has taken place.
I0494-1
C
System Board (501-4903-01, 501-5240-01) Clarification of patches (patch matrix) needed to operate E10000 system boards.
I0469-1
R
FDDI 5.0 SAS/DAS Assemblies Sun FDDI SBus Adapter 5.0 SAS/DAS mounting screws may not fit the EMI plate due to excessive plating.
I0468-1
R
System Board (X2761A) and SSP 3.1 After installing SF+ system boards in an E10000 system, domains may not reboot.
I0464-1
C
System Board (X2760A and X2761A) An SSP power patch is required to operate E10000 2760A/2761A system boards.
I0428-1
C
Power Cord (530-2379-01) Existing power cord for US E10000 systems is too long to meet UL requirements.
I0417-1
R
Control Board Powering off alternate control board in an E10000 may result in total platform shutdown.
I0412-1
R
SunATM-155/MFiber SBus Adapter (501-2794-08), SunATM-155/UTP5 SBus Adapter (501-2795-06) SunATM-155 SBus board replacement may render interface unrecognizable.
I0411-1
R
QFE Sbus Card (501-4837-02) The installation of the QFE Sbus Card (X1049A) on an E10000 domain running Solaris 2.5.1 or 2.6HW2 will require 'special instructions' to successfully complete the installation. These instructions are unnecessary if the Enterprise 10000 is running Solaris 2.6 HW3/98 or later.
I0405-4
C
SBus I/O Board (501-4349), SBus Cards FC-AL, Gigabit Ethernet 1.1, SunSwift, or SunFastEthernet SBus cards should not be installed in SBus slots labeled slot 1 on Enterprise 10000 servers.
I0404-1
R
336MHz CPU Module (501-4363) Configuring 336 MHz CPU modules into a Enterprise 10000 system.
I0403-2
R
CPU Modules Failure to handle CPU Modules correctly can result in physical damage. Such damage may result in immediate failure or intermittent failures. The Augat connectors have a greater chance of damage if proper torquing techniques are not followed.
I0396-1
C
Memory

Troubleshooting ECC memory errors using an MM to P translation map for the Enterprise 10000 server.

I0392-1
n/a
A5000 Withdrawal of 45GB StorEdge A5000 support for E10000 servers.
I0388-1
n/a
SSP E10000 System Service Processor may exhibit slow response.
I0375-2
R
n/a E10000 failure information forms continue to be overlooked by SSE's supporting E10000 systems. This form was carefully designed to obtain specific data that is used in the diagnosis and repair of this product. Failure to fill out the form may result in incorrect diagnosis or a decision to scrap the FRU unnecessarily.
I0365-1
n/a
SSP 3.0 SSP 3.1 software upgrade FAQ for Sun Enterprise 10000 systems.
I0364-1
n/a
Solaris 2.6 The Ultra Enterprise 10000 should NOT be mentioned or appear as being supported under Solaris 2.6.
n/a
n/a Use of interconnect tests during installation/upgrade of E10000 system. To address concern regarding seating problems and to collect data in order to determine the scope of such problems, we are releasing a procedure for interconnect testing between the centerplane and the system boards, as well as interconnect testing on the system board level between the board and CPU, I/O, and memory mezzanines.
I0344-1
n/a
System Board Cover (407-6575-012 Rev 04) A few defective covers have been identified on the Ultra Enterprise 10000 system boards. The cover is missing a clearance hole for a centerplane guidepin. This is ONLY needed for slot 07 on the UE10000, all other slots do not require this clearance hole.
I0342-1
n/a
n/a Procedure for relocating a UE10000 system when the system's networking info changes.
I0338-3
n/a
System Board E10000 system board handling and cleaning procedure.
I0331-2
n/a
n/a Domain unbootable if the value for dr-max-mem is set too large.
I0326-1
n/a
n/a FRU parts returned to Business Systems Division repair depot without failing information is impacting the FRU part repair cycle time.

 

WebToneWebToneWebToneWebTone
 Copyright 1994-2003 Sun Microsystems, Inc.,  901 San Antonio Road, Palo Alto, CA 94303 USA.  All rights reserved.
 Legal Terms Privacy Policy Feedback