NAME

 llc2_config - configure LLC2 interface parameters

SYNOPSIS

 /usr/lib/llc2/llc2_config [ -P | -U | -d | -q | -i ppa | -r ppa]

DESCRIPTION

 

The llc2_config utility is used to start/stop the LLC2 subsystem and to configure LLC2 interface parameters.

OPTIONS

 

The following options are supported:

-d
Turns on debug mode. Extra debugging information will be printed out.
-i ppa
Initializes the corresponding interface using the file /etc/llc2/default/llc2.ppa.
-P
Reads in all /etc/llc2/default/llc2.* configuration files, opens those devices defined in the files, and sets up the streams needed for LLC2 to use those devices. Before doing this, llc2_config -q will not show anything.
-q
Queries the LLC2 subsystem. Information similar to the following example will be printed out for all PPAs (Physical Point of Attachment) available under the LLC2 module:

PPAStateIDMACAddrTypeMaxSDUMinSDUMode
0up00000800208a217eethernet150003

The fields displayed are described below:

PPA
The relative logical position of the interface.
State
The state of the interface:
up
The interface is initialized and operational.
down
The interface was "discovered" by the LLC2 driver, has passed its bootup diagnostics, and is awaiting initialization.
bad
The interface is known to the LLC2 driver, but failed one or more of the integrity checks performed at boot time. This might include detecting Interrupt Request and shared memory conflicts or failures detected during the execution of the level 0 diagnostics.
ID
The interface ID.
MACAddr
The MAC address currently in effect for the interface.
Type
The MAC type. Current types supported include:
csma/cd
10 Megabit Ethernet
ethernet
Ethernet type device
tkn-ring
4/16 Megabit Token Ring
fddi
100 Megabit Fiber Distributed Data Interface
MaxSDU
The Maximum Service Data Unit size transmitted on this interface.
Mode
The Service Modes supported by this interface. This field consists of the bitwise logical-ORing of the supported modes, also defined in /usr/include/sys/dlpi.h.

-r ppa
Uninitializes the corresponding interface. By using this option, and then using the -i option, the parameters associated with an interface can be changed.
-U
Destroys all streams used by the LLC2 subsystem. This is the reverse of the -P option. After this is executed, llc2_config -q will not show anything.

FILES

 
/etc/llc2/default/llc2.*
LLC2 configuration files

ATTRIBUTES

 

See attributes(5) for descriptions of the following attributes:

ATTRIBUTE TYPEATTRIBUTE VALUE
AvailabilitySUNWllc

SEE ALSO

 

llc2_autoconfig(1), llc2(4), attributes(5), llc2(7D)


SunOS 5.9Go To TopLast Changed 18 May 1999

 
      
      