|
System Administration Commands | cg14config(1M) |
| cg14config - configure the cgfourteen device |
SYNOPSIS
| /usr/platform/ platform-name /sbin/cg14config [-d device] [-r resolution] [-g gammavalue] [-G gammafile] [-u degammavalue] [-U degammafile] |
|
cg14config sets up state on the selected cgfourteen device. platform-name can be found using the -i option of uname(1).
cg14config is supported only on Desktop SPARCsystems with SX graphics option.
The interface, output, and command location are uncommitted and subject to change in future releases.
|
|
- -d device
- Use device as the cgfourteen device
to configure. Default is /dev/fb.
- -r resolution
- Use resolution as the desired screen resolution. Resolution is specified in
terms of screen width and height (in pixels), and vertical refresh (in hz). Available resolutions are:
|
1024x768@60
1024x768@66
1024x768@70
1152x900@66
1152x900@76
1280x1024@66
1280x1024@76
1600x1280@66
1920x1080@72
|
The default is the value read from the monitor sense codes. Note that some or all of the resolutions above may not be supported by any given monitor. If a programmed resolution is outside of the
range of allowable values for a monitor, unpredictable results can occur, including damage to the monitor. Thus, care should be taken when programming the resolution. See Openboot Command Reference for a description of how to reset the console device to the default value if it becomes unusable from programming an unsupported resolution.
The -r option is not available when the window system is running.
- -g gammavalue
- Each entry of the gamma lookup table will be loaded with entry^(1/gammavalue).
The gamma lookup table has 256 entries. Default gammavalue is 2.2.
- -G filename
- Initialize the gamma lookup table with the contents of filename. The format of
filename is 256 triplets (red green blue) of non-negative integers separated by NEWLINE characters. The integers must be in the range 0 to 1023, inclusive.
- -u degammavalue
- Each entry of the degamma lookup table will be loaded with entry^(degammavalue).
The degamma lookup table has 256 entries. Default degammavalue is 2.2.
- -U filename
- Initialize the degamma lookup table with the contents of filename. The format
of filename is 256 entries of non-negative integers separated by NEWLINE characters. The integers must be in the range 0 to 255, inclusive.
|
|
cg14config returns 0 on success and a positive integer on failure.
-
1
- Selected device is not a cgfourteen device.
-
2
- Requested action failed.
-
3
- Unsupported resolution.
-
4
- Gamma or degamma value out of range.
|
|
-
/platform/platform-name/kernel/drv/cgfourteen
-
cgfourteen device driver
|
|
See attributes(5) for descriptions of the following
attributes:
ATTRIBUTE TYPE | ATTRIBUTE VALUE |
Availability | SUNWkvm |
|
| |