Sun Microsystems, Inc.
spacerspacer
spacer   www.sun.com docs.sun.com | | |  
spacer
black dot
   
A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z
    
 
System Administration Commandswrsmconf(1M)


NAME

 wrsmconf - manage WCI RSM controller configurations

SYNOPSIS

 /opt/SUNWwrsm/bin/wrsmconf create -c controller_id -f config_file
 wrsmconf initial -f config_file [ -c controller_id]
 wrsmconf remove [ -c controller_id]
 wrsmconf topology [ -c controller_id]
 wrsmconf dump -c controller_id -f config_file

DESCRIPTION

 

wrsmconf provides a means to create, install, retrieve, and remove configurations for WCI remote shared memory (RSM) controllers.

OPTIONS

 

The following options are supported:

create -c controller_id -f config_file
Create a set of per-node configurations for the specified controller and store them to the file config_file. The created file contains a per-node configuration for each node specified in the input for the specified controller. The file has a checksum on it and cannot be modified directly. This file can be used in a wrsmconf initial call on each node to install the node's configuration into the local driver.

A list of nodes and WCI devices connected to those nodes is read from standard input. For each connected pair of links, specify the nodename (uname -n), safari port id, and link number on both sides of the connection. The format of the information looks like this:

 
<nodename>.<wrsm-portid>.<linkno>=<nodename>.<wrsm-portid>.<linkno>
<nodename>.<wrsm-portid>.<linkno>=<nodename>.<wrsm-portid>.<linkno>

This interface is intended for installing configurations for testing (such as for SunVTS). Only direct-connect, non-striped configurations for 1 to 3 nodes can be specified. FM node ids and RSM hardware addresses are assigned to the specified nodes contiguously and in order starting from 0.

initial -f config_file [-c controller_id]
Install the configuration for the local node stored in the file config_file into the driver as the initial configuration for the specified controller. This command fails under the following circumstances:
  • If controller_id is specified and the configuration in the file is not for the specified controller.
  • If the file does not contain a valid configuration for the local node or if the checksum in the file shows it has been modified.
  • If a configuration has already been installed for the controller. If this happens, use wrsmconf remove to remove the existing configuration.
remove [ -c controller_id ]
Disable communication through the installed configuration for all controllers or the specified controller and remove the configuration(s) from the driver.
topology -c controller_id
For each installed controller (or for the specified controller), print to stdout the set of nodes this controller is configured to reach, including the nodename, FM node id, and RSM hardware address for each node. The following is example output:

 
FM Node ID   Node Name  Controller Instance    Controller HW Addr 
0            hpc00              0                    101
0            hpc00              1                    333
1            hpc01              0                    102
1            hpc01              1                    54
1            hpc01              2                    34
2            hpc03              0                    103
2            hpc03              1                    103
2            hpc03              2                    103

dump -c controller-id -f config_file
Fetch the installed configuration for the specified controller from the driver and store it into the file config_file along with a checksum to protect the data. This configuration can later be installed with the command wrsmconf initial.

EXIT STATUS

 

This command returns 0 on successful completion, and a non-zero value if an error occured.

ATTRIBUTES

 

See attributes(5) for descriptions of the following attributes:

ATTRIBUTE TYPEATTRIBUTE VALUE
AvailabilitySUNWwrsm

SEE ALSO

 

kstat(1M), wrsmstat(1M), attributes(5)


SunOS 5.9Go To TopLast Changed 22 Mar 2001

 
      
      
Copyright 2002 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms.