Error for command '<command name>' Error Level: Fatal Requested Block <n>,
Error Block: <m>, Sense Key: <sense key name>, Vendor '<vendor name>':
ASC = 0x<a> (<ASC name>), ASCQ = 0x<b>, FRU = 0x<c>
|
The command indicated by <command name> failed. The Requested Block
is the block where the transfer started and the Error Block is the block that
caused the error. Sense Key, ASC, and ASCQ information is returned by the
target in response to a request sense command.
|
Check Condition on REQUEST SENSE
|
A REQUEST SENSE command completed with a check condition. The original
command will be retried a number of times.
|
Label says <m> blocks Drive says <n> blocks
|
There is a discrepancy between the label and what the drive returned
on the READ CAPACITY command.
|
Not enough sense information
|
The request sense data was less than expected.
|
Request Sense couldn't get sense data
|
The REQUEST SENSE command did not transfer any data.
The drive was reserved by another initiator.
|
SCSI transport failed: reason 'xxxx' : {retrying|giving up}
|
The host adapter has failed to transport a command to the target for
the reason stated. The driver will either retry the command or, ultimately,
give up.
The REQUEST SENSE data included an invalid sense key.
|
Unit not Ready. Additional sense code 0x<n>
|
The drive is not ready.
|
corrupt label - bad geometry
|
The disk label is corrupted.
|
corrupt label - label checksum failed
|
The disk label is corrupted.
|
corrupt label - wrong magic number
|
The disk label is corrupted.
The drive returned busy during a number of retries.
|
disk not responding to selection
|
The drive was probably powered down or died.
The geometry of the drive could not be established.
|
incomplete read/write - retrying/giving up
|
There was a residue after the command completed normally.
The drive is not ready.
A bp with consistent memory could not be allocated.
Free memory pool exhausted.
Free memory pool exhausted.
A packet could not be allocated during dumping.
Drive went offline; probably powered down.
|
requeue of command fails<n>
|
Driver attempted to retry a command and experienced a transport error.
|
ssdrestart transport failed <n>
|
Driver attempted to retry a command and experienced a transport error.
|
transfer length not modulo <n>
|
Illegal request size.
Host adapter driver was unable to accept a command.
Failure to read disk label.
|
unit does not respond to selection
|
Drive went offline; probably powered down.
|