Sun Microsystems, Inc.
spacerspacer
spacer   www.sun.com docs.sun.com | | |  
spacer
black dot
   
A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z
    
 
Devicesssd(7D)


NAME

 ssd - driver for SPARCstorage Array and Fibre Channel Arbitrated Loop disk devices

SYNOPSIS

 
ssd@port,target:partition

DESCRIPTION

 

This driver handles both SCSI-2 disks in the SPARCstorage Array and Fibre Channel Arbitrated Loop (FC-AL) disks on Private loops.

The specific type of each disk is determined by the SCSI inquiry command and reading the volume label stored on block 0 of the drive. The volume label describes the disk geometry and partitioning; it must be present or the disk cannot be mounted by the system.

The block-files access the disk using the system's normal buffering mechanism and are read and written without regard to physical disk records. There is also a "raw" interface that provides for direct transmission between the disk and the user's read or write buffer. A single read or write call usually results in one I/O operation; raw I/O is therefore considerably more efficient when many bytes are transmitted. The names of the block files are found in /dev/dsk; the names of the raw files are found in /dev/rdsk.

I/O requests (such as lseek(2)) to the SCSI disk must have an offset that is a multiple of 512 bytes (DEV_BSIZE), or the driver returns an EINVAL error. If the transfer length is not a multiple of 512 bytes, the transfer count is rounded up by the driver.

Partition 0 is normally used for the root file system on a disk, partition 1 as a paging area (for example, swap), and partition 2 for backing up the entire disk. Partition 2 normally maps the entire disk and may also be used as the mount point for secondary disks in the system. The rest of the disk is normally partition 6. For the primary disk, the user file system is located here.

Each device also has error statistics associated with it. These must include counters for hard errors, soft errors and transport errors. Other data may be implemented as required.

DEVICE STATISTICS SUPPORT

 

Each device maintains I/O statistics for the device and for partitions allocated for that device. For each device/partition, the driver accumulates reads, writes, bytes read, and bytes written. The driver also initiates hi-resolution time stamps at queue entry and exit points to enable monitoring of residence time and cumulative residence-length product for each queue.

Not all device drivers make per-partition IO statistics available for reporting. ssd and sd(7D) per-partition statistics are enabled by default but may disabled in their configuration files.

IOCTLS

 

Refer to dkio(7I).

ERRORS

 
EACCES
Permission denied.
EBUSY
The partition was opened exclusively by another thread.
EFAULT
The argument was a bad address.
EINVAL
Invalid argument.
EIO
An I/O error occurred.
ENOTTY
The device does not support the requested ioctl function.
ENXIO
When returned during open(2), this error indicates the device does not exist.
EROFS
The device is a read-only device.

CONFIGURATION

 

The ssd driver can be configured by defining properties in the ssd.conf file. The ssd driver supports the following properties:

enable-partition-kstats
The default value is 1, which causes partition IO statistics to be maintained. Set this value to zero to prevent the driver from recording partition statistics. This slightly reduces the CPU overhead for IO, mimimizes the amount of sar(1) data collected and makes these statistics unavailable for reporting by iostat(1M) even though the -p/-P option is specified. Regardless of this setting, disk IO statistics are always maintained.

FILES

 
ssd.conf
driver configuration file
/dev/dsk/cntndnsn
block files
/dev/rdsk/cntndnsn
raw files

where, for the SPARCstorage Array:

cn
is the controller number on the system. Each SPARCstorage Array will have a unique controller number
tn
port number within the SPARCstorage Array n
dn
SCSI target n
sn
partition n

and for all FC-AL disks:

cn
is the controller number on the system.
tn
7-bit disk loop identifier, such as switch setting
dn
SCSI lun n
sn
partition n (0-7)

SEE ALSO

 

sar(1), format(1M), iostat(1M), ioctl(2), lseek(2), open(2), read(2), write(2), driver.conf(4), cdio(7I), dkio(7I)

ANSI Small Computer System Interface-2 (SCSI-2)

SPARCstorage Array User's Guide

ANSI X3.272-1996, Fibre Channel Arbitrated Loop (FC-AL)

Fibre Channel - Private Loop SCSI Direct Attach (FC-PLDA)

DIAGNOSTICS

 
 
Error for command '<command name>' Error Level: Fatal Requested Block <n>, 
Error  Block: <m>, Sense Key: <sense key name>, Vendor '<vendor name>': 
ASC = 0x<a> (<ASC name>), ASCQ = 0x<b>, FRU = 0x<c>

The command indicated by <command name> failed. The Requested Block is the block where the transfer started and the Error Block is the block that caused the error. Sense Key, ASC, and ASCQ information is returned by the target in response to a request sense command.

 
Check Condition on REQUEST SENSE

A REQUEST SENSE command completed with a check condition. The original command will be retried a number of times.

 
Label says <m> blocks Drive says <n> blocks

There is a discrepancy between the label and what the drive returned on the READ CAPACITY command.

 
Not enough sense information

The request sense data was less than expected.

 
Request Sense couldn't get sense data

The REQUEST SENSE command did not transfer any data.

 
Reservation Conflict

The drive was reserved by another initiator.

 
SCSI transport failed: reason 'xxxx' : {retrying|giving up} 

The host adapter has failed to transport a command to the target for the reason stated. The driver will either retry the command or, ultimately, give up.

 
Unhandled Sense Key <n>

The REQUEST SENSE data included an invalid sense key.

 
Unit not Ready. Additional sense code 0x<n>

The drive is not ready.

 
corrupt label - bad geometry

The disk label is corrupted.

 
corrupt label - label checksum failed

The disk label is corrupted.

 
corrupt label - wrong magic number

The disk label is corrupted.

 
device busy too long

The drive returned busy during a number of retries.

 
disk not responding to selection

The drive was probably powered down or died.

 
i/o to invalid geometry

The geometry of the drive could not be established.

 
incomplete read/write - retrying/giving up

There was a residue after the command completed normally.

 
logical unit not ready

The drive is not ready.

 
no bp for disk label

A bp with consistent memory could not be allocated.

 
no mem for property

Free memory pool exhausted.

 
no memory for disk label

Free memory pool exhausted.

 
no resources for dumping

A packet could not be allocated during dumping.

 
offline

Drive went offline; probably powered down.

 
requeue of command fails<n>

Driver attempted to retry a command and experienced a transport error.

 
ssdrestart transport failed <n>

Driver attempted to retry a command and experienced a transport error.

 
transfer length not modulo <n>

Illegal request size.

 
transport rejected <n>

Host adapter driver was unable to accept a command.

 
unable to read label

Failure to read disk label.

 
unit does not respond to selection

Drive went offline; probably powered down.


SunOS 5.9Go To TopLast Changed 21 Feb 2001

 
      
      